Scope of annex
This annex covers frequency bands and regulatory as well as informative parameters recommended for the application of model control equipment, which is solely for the purpose of controlling the movement of the model, in the air, on land or over or under the water surface. Although the bands are not harmonised, the parameters given in the table are common in a majority of CEPT countries. It should be noted that the bands are not exclusive for this type of application.
Frequency Band | Power / Magnetic Field | Spectrum access and mitigation requirements | Modulation /occupied bandwidth | ECC/ERC Deliverable | Notes | |
---|---|---|---|---|---|---|
a1 | 26990kHz - 27000kHz |
100 mW e.r.p. | No requirement | ≤ 10 kHz | ||
a2 | 27040kHz - 27050kHz |
100 mW e.r.p. | No requirement | ≤ 10 kHz | ||
a3 | 27090kHz - 27100kHz |
100 mW e.r.p. | No requirement | ≤ 10 kHz | ||
a4 | 27140kHz - 27150kHz |
100 mW e.r.p. | No requirement | ≤ 10 kHz | ||
a5 | 27190kHz - 27200kHz |
100 mW e.r.p. | No requirement | ≤ 10 kHz | ||
b | 34.995MHz - 35.225MHz |
100 mW e.r.p. | No requirement | ≤ 10 kHz | ERC/DEC/(01)11 | Only for flying models |
c1 | 40.66MHz - 40.67MHz |
100 mW e.r.p. | No requirement | ≤ 10 kHz | ERC/DEC/(01)12 | |
c2 | 40.67MHz - 40.68MHz |
100 mW e.r.p. | No requirement | ≤ 10 kHz | ERC/DEC/(01)12 | |
c3 | 40.68MHz - 40.69MHz |
100 mW e.r.p. | No requirement | ≤ 10 kHz | ERC/DEC/(01)12 | |
c4 | 40.69MHz - 40.7MHz |
100 mW e.r.p. | No requirement | ≤ 10 kHz | ERC/DEC/(01)12 |
Harmonised Standards
EN 300 220 all sub-bands
Technical parameters also referred to in the
harmonised standard
No information
Frequency issues
No information